|
|
|
|
Vous souhaitez une assistance à la configuration?
Appelez l’un de nos spécialiste.
|
|
|
| |
|
|
|
Thermo Electron PDR-1000AN
|
|
|
PDR-1000 Hand-Held Real-Time Aerosol Monitor
|
|
|
| Modèle | Options Incluses |
|
Sélectionnez les Articles
|
LOCATION LEASING |
ACHAT d’OCCASION |
|
| TE-PDR-1000AN | |
|
|
|
| Description du Catalogue |
Thermo Electron PDR-1000AN The pDR-1000AN Personal Dataram (pdr) measures airborne particulates concentration in real time, storing this information in detail for subsequent retrieval/printout/graphing through a computer. Range: 0.001 to 400 mg/m3. Palm-sized, the Personal Dataram weighs only 1/2 kilogram (18 oz.). Power options include replaceable 9V alkaline "transistor" battery which provides up to 12 hours of operation, AC line power, an optional 48 hour rechargeable battery pack or external DC (7 to 9V lantern battery). Applications: Indoor air quality monitoring Walk-Through surveys Personal exposure monitoring Time and motion studies Workplace and plant monitoring Remediation site worker surveillance Remote alarming Mobile monitoring in vehicles and aircraft Unattended long-term monitoring pDR-1000AN is the Passive Sampling version (requires no vacuum pump) Specifications: Accuracy: +/-5% of reading +/- precision Particle Size Range of Maximum Response: 0.1 to 10 um Resolution: 0.1% of reading or 0.001 mg/m3, whichever is larger Concentration Display Updating Interval: 1 second Concentration Measurement Ranges (auto ranging): 0.001 to 400 mg/m3 Alarm Level Adjustment Range (user selectable): Selectable over entire measurement range Alarm Averaging Time (user selectable): Real-Time (1-60 seconds) or STEL (15 minutes) Data Logging Averaging Periods (user selectable): 1 second to 4 hours Logged Data (each data point): Average concentration, time/date and data point number Logged Data (run summary): Overall average and maximum concentrations, time/date of maximum, total number of logged points, start time/date, total elapsed time (run duration), STEL concentration and time/date of occurrence, averaging (logging) period, calibration factor, and tag number. Total Number of Data Points in Memory: 13,000 Number of Data Tags: 99 Elapsed Time Readout Range: 0 to 100 hours (resets to 0 after 100 hours) Time Keeping and Data Retention: Greater than 10 years Readout Display: LCD 16 characters (4 mm height) x 2 lines Serial Interface: RS232, 4,800 baud Computer Requirements: PC compatible, 486 or higher; Windows 95 or higher Power: Internal battery: 9V alkaline, 20 hours run time (typical); AC source: universal voltage adapter (included) 100-250 volts, 50-60Hz (CE marked); Optional battery pack: rechargeable NiMH 72 hour run time (typical) Operating Environment: -10 to 50 degrees C (14 to 122 degrees F); 10 to 95% RH, non-condensing Storage Environment: -20 to +70 degrees C (-4 to +158 degrees F) |
|
|
|
|
|
Vous souhaitez une assistance à la configuration? Appelez l'un de nos spécialiste au numéro vert 00800 1234 40 40 ou +32 15 740 800.
|
|
| |
|
|